Details
KAAS – Personnel Air Shower Series
Models: KAAS-A1, KAAS-B1, KAAS-C1 and customised multi-person configurations
Brand: KAAS
Product Type: Cleanroom Personnel Air Shower
Overview
The KAAS Personnel Air Shower is designed to reduce loose dust and particulate contamination carried by personnel before they enter a cleanroom or controlled production area.
Installed between clean and non-clean zones, the air shower uses high-velocity, HEPA-filtered air jets to remove loose particles from cleanroom garments, hair and exposed surfaces. The entry and exit doors are electrically interlocked, allowing the chamber to function as an airlock and helping reduce the direct transfer of unfiltered air into the clean area.
The series is available with different airflow velocities, chamber lengths and airflow arrangements. Standard configurations include single-person straight-through models, while longer chambers and wider multi-person versions can be customised according to the facility layout and personnel traffic.
The catalogue lists standard single-person models with internal dimensions of approximately 800 × 910 × 1980 mm, adjustable shower cycles, G4 pre-filtration and HEPA filtration stated above 99.99% efficiency at 0.3 μm.
Applications
-
Cleanroom personnel entry
-
Pharmaceutical manufacturing
-
Medical-device production
-
Semiconductor facilities
-
Electronics and PCB manufacturing
-
Food-processing plants
-
Biotechnology laboratories
-
Cosmetic production
-
Battery manufacturing
-
Precision engineering
-
Optical-component manufacturing
-
Controlled packaging areas
-
Research laboratories
-
Dust-controlled production environments
How the Personnel Air Shower Works
-
The operator enters the air shower chamber.
-
The entry door closes and the electrical interlock is activated.
-
The blower draws air through the G4 pre-filter and HEPA filtration system.
-
Clean air is discharged through stainless-steel nozzles at high velocity.
-
Loose particles are removed from the operator’s garments and body surface.
-
Return air is recirculated through the filtration system.
-
Once the programmed shower cycle is completed, the clean-side door is released.
The catalogue describes the air shower as a transition device between clean and non-clean areas, with interlocked doors helping prevent unfiltered air from directly entering the cleanroom.
Available Models
|
Model |
External Dimensions |
Internal Dimensions |
Air Velocity |
Typical Airflow |
|
KAAS-A1 |
1400 × 1000 × 2100 mm |
800 × 910 × 1980 mm |
25–30 m/s |
Two-side or three-side |
|
KAAS-B1 |
1240 × 1000 × 2100 mm |
800 × 910 × 1980 mm |
20–25 m/s |
Two-side or three-side |
|
KAAS-C1 |
1200 × 1000 × 2100 mm |
800 × 910 × 1980 mm |
Approximately 15–20 m/s |
One-side standard, two-side optional |
These KAAS model names are recommended website codes based on the source configurations. Final model naming should follow the approved commercial quotation.
Extended Personnel Air Shower Models
|
Configuration |
External Dimensions |
Internal Dimensions |
Air Velocity |
|
KAAS-A2 |
1400 × 1500 × 2100 mm |
800 × 1410 × 1980 mm |
25–30 m/s |
|
KAAS-B2 |
1240 × 1500 × 2100 mm |
800 × 1410 × 1980 mm |
20–25 m/s |
|
KAAS-A3 |
1400 × 2000 × 2100 mm |
800 × 1910 × 1980 mm |
25–30 m/s |
|
KAAS-B3 |
1240 × 2000 × 2100 mm |
800 × 1910 × 1980 mm |
20–25 m/s |
|
KAAS-D1 |
2000 × 2000 × 2100 mm |
1400 × 1910 × 2020 mm |
25–30 m/s |
|
KAAS-D2 |
2000 × 2000 × 2100 mm |
1400 × 1910 × 1980 mm |
25–30 m/s |
Longer and wider versions are suitable for multiple personnel, higher traffic volume or project-specific cleanroom layouts. The source catalogue confirms that chamber sizes can be customised.
Technical Specifications
|
Parameter |
Typical Specification |
|
Brand |
KAAS |
|
Product |
Personnel Air Shower |
|
Chamber Type |
Straight-through cleanroom entry system |
|
Internal Width |
Approximately 800 mm for standard single-person models |
|
Internal Height |
Approximately 1980 mm |
|
Air Velocity |
Approximately 15–30 m/s, depending on model |
|
HEPA Filter |
570 × 570 × 69 mm, 1 piece |
|
HEPA Efficiency |
Stated above 99.99% at 0.3 μm |
|
Pre-filter |
G4, 1 piece |
|
Shower Type |
Adjustable, 0–99 seconds |
|
Door Type |
Manual swing door |
|
Door Interlock |
Eletrical Interlock |
|
Viewing Panel |
5 mm tempered glass |
|
Blower |
Direct-drive centrifugal blower |
|
Air Nozzle |
Stainless Steel |
|
Airflow Arrangement |
One-side, two-side or three-side |
|
Power |
Approximately 1100 W |
|
Voltage |
110–440 V, 50/60 Hz depending on configuration |
|
Construction |
Powder-coated steel, SS201, SS304 or SS316 |
|
Installation |
Floor-mounted cleanroom entry system |
Final specifications must follow the selected KAAS configuration and approved project drawing.
Key Features
High-Velocity Particle Removal
-
Air velocity options from approximately 15 to 30 m/s
-
Designed to remove loose particles from cleanroom garments
-
Multiple nozzle arrangements for improved body coverage
-
Suitable for routine cleanroom personnel entry
HEPA Filtration
-
HEPA filtration stated above 99.99% efficiency at 0.3 μm
-
G4 pre-filter helps capture larger airborne particles
-
Pre-filtration supports longer HEPA filter service life
-
Recirculating airflow reduces unnecessary conditioned-air loss
Electrical Door Interlock
-
Entry and exit doors cannot normally open simultaneously
-
Helps the chamber operate as an airlock
-
Reduces direct airflow between clean and non-clean areas
-
Emergency-stop arrangement available depending on configuration
Programmable Operation
-
Adjustable shower time from 0 to 99 seconds
-
Operating sequence can be configured according to site procedure
-
Suitable for different contamination-control requirements
-
User controls can be customised according to project needs
Flexible Airflow Configuration
-
One-side airflow
-
Two-side airflow
-
Three-side airflow
-
Optional ceiling airflow
-
Custom nozzle quantity and positioning
Durable Construction
-
Powder-coated steel option
-
Stainless steel SS201
-
Stainless steel SS304
-
Stainless steel SS316
-
Tempered-glass viewing panels
-
Stainless-steel air nozzles
Construction Material Options
Powder-Coated Steel
Suitable for:
-
General industrial cleanroom entry
-
Cost-sensitive projects
-
Controlled indoor environments
Stainless Steel SS304
Recommended for:
-
Pharmaceutical facilities
-
Food-processing areas
-
Medical-device manufacturing
-
Laboratories
-
Higher-cleanliness applications
Stainless Steel SS316
Suitable where:
-
Stronger corrosion resistance is required
-
Cleaning chemicals are regularly used
-
The project specification specifically requires SS316
Airflow Configurations
One-Side Airflow
Suitable for:
-
Compact installations
-
Lower-budget applications
-
Lower contamination-load environments
Two-Side Airflow
Recommended for:
- Standard personnel applications
- More balanced garment coverage
- General pharmaceutical, electronics and food facilities
Three-Side Airflow
Suitable for:
- Higher contamination-control requirements
- Stronger coverage from side and ceiling nozzles
- Custom cleanroom entry projects
For most personnel applications, two-side airflow provides the best balance between coverage, complexity and cost.
Door and Layout Options
The KAAS Personnel Air Shower can be configured with:
- Straight-through entry
- Opposite entry and exit doors
- Custom left-hand or right-hand door swing
- L-shaped configuration
- Three-door arrangement
- Longer tunnel configuration
- Multi-person chamber
- Custom cleanroom wall integration
Door direction and chamber layout must be confirmed before manufacturing.
Optional Accessories
-
Full SS304 construction
-
SS316 construction
-
Three-side airflow
-
Ceiling air nozzles
-
Automatic sliding doors
-
Touchless sensors
-
Emergency-stop buttons
-
Differential-pressure gauge
-
HEPA filter condition monitoring
-
Door-status indicators
-
Voice instruction system
-
LED chamber lighting
-
Access-card system
-
Password access
-
UV-C lamp
-
Custom chamber dimensions
-
Custom control sequence
-
Custom voltage
-
Cleanroom wall-integration panels
Optional accessories should only be stated as included when confirmed in the final quotation.
Important Application Notes
Cleanroom Classification
The air shower helps reduce particle transfer but does not independently create or guarantee an ISO cleanroom classification.
Cleanroom classification depends on:
- HVAC performance
- HEPA filtration
- Room airflow
- Pressure control
- Room construction
- Personnel procedures
- Cleaning and validation
HEPA Filter Grade
The catalogue states filtration performance above 99.99% at 0.3 μm. The specific filter grade, such as H13 or H14, should be confirmed in the final KAAS technical specification.
Particle Removal Limitation
The air shower is designed to remove loose particles. It does not replace:
- Proper gowning procedures
- Garment cleaning
- Surface wiping
- Personnel hygiene
- Validated sanitation or sterilisation processes
UV or Ozone Systems
UV-C and ozone should be treated as optional supplementary features. They should not be marketed as guaranteed sterilisation unless the dose, exposure time, safety controls and validation have been defined.
Site Preparation
The customer should prepare:
- Confirmed installation opening
- Available floor area
- Cleanroom wall dimensions
- Required door direction
- Electrical supply
- Floor level and loading capacity
- Installation and service clearance
- Personnel traffic information
- Cleanroom classification
- Preferred construction material
- Clean-side and non-clean-side layout
- Safe access for delivery and installation
Warranty & After-Sales Support
-
Warranty according to the confirmed commercial quotation
-
Installation and commissioning
-
Operator training
-
Air-velocity verification
-
Door-interlock functional testing
-
Preventive-maintenance guidance
-
HEPA and pre-filter replacement support
-
Blower, controller and interlock troubleshooting
-
Spare-parts coordination
-
Local technical support in Malaysia
Customer Service Commitment
Redmark Industry supports KAAS personnel air shower projects through:
- Cleanroom entry-point assessment
- Chamber-size selection
- Airflow configuration recommendation
- Door-direction planning
- Material-of-construction selection
- Electrical requirement confirmation
- Site-preparation guidance
- Installation coordination
- Commissioning
- Operator familiarisation
- Maintenance planning
- After-sales technical support
Enquiry Information Required
To recommend the correct KAAS Personnel Air Shower, please provide:
- Cleanroom layout
- Available installation space
- Required internal chamber size
- Number of personnel per cycle
- Personnel traffic frequency
- Preferred construction material
- Required door direction
- Required airflow arrangement
- Electrical supply
- Cleanroom classification
- Wall thickness and opening dimensions
- Any access-control requirements
View more about KAAS - PERSONNEL AIR SHOWER on main site